Design, construction and evaluation of a new laboratory convective dryer using CFD

dc.contributor.authorTzempelikos, Dimitrios
dc.contributor.authorVouros, Alexandros
dc.contributor.authorBardakas, Achilleas
dc.contributor.authorFilios, Andronikos
dc.contributor.authorMargaris, Dionissios
dc.contributor.otherΤζεμπελίκος, Δημήτριος
dc.contributor.otherΒούρος, Αλέξανδρος
dc.contributor.otherΜπαρδάκας, Αχιλλέας
dc.contributor.otherΦιλιός, Ανδρόνικος
dc.contributor.otherΜάργαρης, Διονύσιος
dc.date.accessioned2013-12-10T10:07:42Z
dc.date.available2013-12-10T10:07:42Z
dc.date.copyright2013-10-25
dc.date.issued2013-12-10
dc.description.abstractIn order to overcome the lack of experimental data in the open literature and the necessity to validate numerical models, as well as increase the efficiency of the drying process, a new laboratory convective (LC) dryer has been designed, constructed and equipped with an integrated measurement and automated control instrumentation. The main sections of the LC dryer, which can be arranged for operation in a closed or open circuit mode through manually controlled dumpers, are the vertical flow drying chamber,the tube heat exchanger, the thermal boiler and finally the fan - motor with a smooth speed control unit. The experimental facility tested and monitored the moisture content removal of horticultural and agricultural products. The current paper outlines the methodology applied for the design and optimization of the LC dryer, which has been achieved through the analysis of the flow field by means of computational fluid dynamics (CFD). The prediction of the 3d flow problem was accomplished through the solution of the steady-state incompressible, Reynolds-Averaged Navier-Stokes (RANS) equations with the incorporation of the standard k-ε turbulence model. The measurement and control instrumentation with the inclusion of the innovative, pc-controlled, 3d traverse system that serves detailed surveys of the temperature and velocity inside the drying chamber, are also discussed. The performance test and evaluation of the LC dryer was conducted using quince slices as a test material at an average temperature of 60oC and air at 2 m/s into the drying chamber.el
dc.description.translatedabstract-el
dc.identifierDesign, construction and evaluation of a new laboratory convective dryer using CFDel
dc.identifier.urihttp://hdl.handle.net/10889/6535
dc.language.isoen_USel
dc.sourceInternational Journal of Mechanicsel
dc.subjectComputational fluid dynamics (CFD)el
dc.subjectConvective dryerel
dc.subjectDesignel
dc.subjectDrying kineticsel
dc.subject.alternativeΥπολογιστική ρευστοδυναμικήel
dc.titleDesign, construction and evaluation of a new laboratory convective dryer using CFDel
dc.typeJournal (paper)el
dcterms.extent425-434el

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
d102003-095.pdf
Size:
1.21 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
5.31 KB
Format:
Item-specific license agreed upon to submission
Description: