Estimation and analysis of uncertainties in patient position during 3D Conformal Radiation Therapy

dc.contributor.advisorΕυσταθόπουλος, Ευστάθιος
dc.contributor.authorΜυλωνά, Βασιλική
dc.contributor.committeeΠαναγιωτάκης, Γεώργιος
dc.contributor.committeeΣακελλαρόπουλος, Γεώργιος
dc.contributor.otherMylona, Vasiliki
dc.date.accessioned2019-06-30T09:58:12Z
dc.date.available2019-06-30T09:58:12Z
dc.date.copyright2019-03-27
dc.degreeΜεταπτυχιακή Εργασίαel
dc.description.abstractThis thesis introduces the concept of patient Set-up uncertainties, underlines their significance in a Radiotherapy Department and presents an evaluation of the magnitude of such uncertainties in the Radiotherapy Department of the ‘’Attikon’’ General University Hospital of Athens. In this research 90 patients were examined in total. An Off-line protocol was introduced in order to detect the Set-up errors in patient positioning. The cases of interest were the following: Head and Neck, Thorax and Pelvis. In this protocol the Radiation Oncologist examined the acquired Portal Films and compared them with the digital reconstructed radiograms (DRRs). Patient shifts were applied in order improve the patient positioning accuracy whenever it was considered necessary. A large number of related parameters was noted for each imaging session. Additionally, the ‘Van Herk’ formula was used to calculate the CTV to PTV Margins for every treatment case. Finally, the margins that were calculated were compared with the margins that are being used by the physicians in the’ ATTIKON’ Radiotherapy Department, to evaluate the adequate dosimetric coverage of the targets and the adequate protection of normal tissue volumes during patient irradiation.  el
dc.description.translatedabstract--el
dc.identifier.urihttp://hdl.handle.net/10889/12202
dc.language.isoenel
dc.rights0el
dc.subjectRadiotherapyel
dc.subject‘’Attikon’’ General University Hospitalel
dc.subjectVan Herk formulael
dc.subject.alternativeΡαδιοθεραπείαel
dc.subject.alternativeΓενικό Νοσοκομείο "Αττικόν"el
dc.subject.ddc615.842el
dc.titleEstimation and analysis of uncertainties in patient position during 3D Conformal Radiation Therapyel
dc.typeThesisel

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
MylonaVthesis2-2-19gp.pdf
Size:
1.56 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
5.05 KB
Format:
Item-specific license agreed upon to submission
Description: