Breast dose distribution studies in magnification mammography using Monte Carlo simulation

dc.contributor.advisorΠαναγιωτάκης, Γεώργιος
dc.contributor.authorΚουταλώνης, Ματθαίος Β.
dc.contributor.committeeΠαναγιωτάκης, Γεώργιος
dc.contributor.committeeΚωσταρίδου, Λένα
dc.contributor.committeeΟικονόμου, Γεώργιος
dc.contributor.otherKoutalonis, Matthaios V.
dc.date.accessioned2008-12-12T07:55:25Z
dc.date.available2008-12-12T07:55:25Z
dc.date.copyright2006
dc.date.issued2008-12-12T07:55:25Z
dc.degreeΜεταπτυχιακή Εργασίαen
dc.description.abstractMagnification mammography is a special technique used in cases where breast complaints are noticed by a woman or when an abnormality is found in a screening mammogram. The carcinogenic risk in mammography is related to the dose deposited in the glandular tissue of the breast rather than the adipose, and Average Glandular Dose (AGD) is the quantity taken into consideration during a mammographic exam. Direct measurement of the AGD is not feasible during clinical practice and thus, the incident air Kinetic Energy Released per unit of MAss (KERMA) on the breast surface is used to estimate the glandular dose, with the help of proper conversion factors. Additional conversion factors adapted for magnification and tube voltage are calculated, using Monte Carlo simulation. The effect of magnification factor, tube voltage and various anode/filter material combinations on AGD, ESD and PDD is also studied. Results demonstrate that, for fixed glandularity, the estimation of AGD utilizing conversion factors depends on magnification factor, anode/filter combination and tube voltage applied. AGD was found to increase mainly with filter material’s kabsorption edge, filter’s Al thickness, anode material’s k-emission edge and tube voltage. Rh/Nb, W/Zr, W/Nb, W/Mo and Mo/Nb are combinations resulting in lower AGD and higher ESD, compared to the Mo/Mo one.en
dc.description.translatedabstract-en
dc.identifier.urihttps://hdl.handle.net/10889/1162
dc.language.isogren
dc.relation.isformatofΗ ΒΥΠ διαθέτει αντίτυπο της διατριβής σε έντυπη μορφή στο βιβλιοστάσιο διδακτορικών διατριβών που βρίσκεται στο ισόγειο του κτιρίου της.en
dc.rights0en
dc.subjectAverage glandular doseen
dc.subjectMagnification mammographyen
dc.subjectMonte Carlo simulationen
dc.subject.alternativeΜέση δόση στο μαζικό αδένα του μαστούen
dc.subject.alternativeΜεγεθυντικές λήψεις στη μαστογραφίαen
dc.subject.alternativeΠροσομοίωση Monte Carloen
dc.subject.ddc618.190 757 2en
dc.titleBreast dose distribution studies in magnification mammography using Monte Carlo simulationen
dc.title.alternativeΜελέτη απορροφώμενης δόσης σε μεγεθυντικές λήψεις στη μαστογραφία με τεχνικές προσομοίωσης Monte Carloen
dc.typeThesisen

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Nimertis_Koutalonis.pdf
Size:
324.76 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
6.78 KB
Format:
Item-specific license agreed upon to submission
Description: